BioSafety Cabinet A2/B2

The name ERFOLG GANAR has long been synonymous with quality and longevity. Our newly redesigned Biosafety is a proud example of this reputation. Over 20 years of experience, combined with state-of-the-art engineering and testing facilities, provide you with a BioSafety Cabinet unsurpassed in quality and Safety should be the number one concern when choosing a BioSaety Cabinet. Biosafety Cabinets (BSCs) are enclosed workspaces with a ventilated hood that is designed to contain pathogenic microorganisms during microbiological processes.

They are supplied at customer-site in a prefabric condition & customer need to be check the pass through standard sized doorways for chambers. The installation & commissioning is accompanied with IQ, OQ, PQ protocols & complete documentation.

Salient Features:
a) A front access opening with careful maintained inward airflow. An internal blower draws sufficient room air through front grill to maintain a minimum calculated or measured average FPM at the face opening of the cabinet.
b) The contaminated air is drawn by the blower through the plenum of the cabinet, were approximately 70% of the air recirculated through the HEPA filter back to the work area, 30% of the air is exhausted from a common plenum at the top through a HEPA filter.
c) Room air enters through a blower / motor passes through a pre-filter in to the work area as the vertical unidirectional airflow.
d) HEPA filter exhaust air in Type A2 cabinet maybe recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.
e) HEPA filter having efficiency rating as high as 99.99% with cold DOP & 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micro and larger.
f) Negative pressure surrounds the work area and maintains inward air flow in chamber.
g) Aerodynamics air flow grill maintains safety and prevents blockage.
h) High efficiency pre-filter use increases the life of HEPA filter.
j) Unit has UV germicidal light for sterilization and fluorescent lamp for illumination.
k) Maximum safe door opening height 8” (Access port – Work aperture) l) Personal protection from harmful agents used inside the biosafety cabinet.
m) Product protection from contamination of the works, experiment or process from outside contaminants.
n) Environment protection from contamination of the works, experiment or process from outside contaminants.
o) Manufactured as per NSF/ANSI 49 USA standard and EN 12469 European guidelines.
p) Machines qualifies particle count test, Filter Integrity Test, Velocity Test, DOA/POA test, Fluorescent Light and UV light test.
q) Machine is fitted with castor wheels for ease of movement and fixed with rubber leveling pad.

Order Information->
Exterior& Interior
is of Structural Polypropylene


Internal Size

External Size

MotorCapacity

Electrical Point UV & White Light Virus BurnOut
(H*W*D) mm (H*W*D) mm
EGBS6P-M 1800 X 762 X 1372 1875 x 900 x 2120 3.0Hp 2 YES Optional
EGBS5P-M 1500 X 762 X 1372 1575 x 900 x 2120 2.0Hp 2 YES Optional
EGFBS4P-M 1200 X 762 X 1372 1275 x 900 x 2120 1.5Hp 2 YES Optional
EGBS3P-M 915 X 762 X 1220 990 x 900 x 1970 1.0Hp 2 YES Optional